Operation Manual Flytec 6015 13
2.2.6 Variometer – climb acoustic
2.2.6.1 Climb acoustic threshold
Main Setup Menu
Variometer Climb Acoustic
Climb threshold
In order to avoid the climb acoustics get started with immobile aircraft, for ex. at take-off area, or at only
slight climb, the climb acoustics starting point can be set in the range from 0 cm/s up to 20 cm/s.
2.2.6.2 Basic frequency
Main Setup Menu
Variometer Acoustic
Basic frequency
The frequency audible at starting climb tone.
Range: 600 -1400 Hz (factory setting 700 Hz)
2.2.6.3 Variometer climb acoustic Frequency change
Main Setup Menu
Variometer Acoustic
Frequency change
The interrelation may be seen on graphic below.
Range: 0 up to 4 (factory setting 2)
3'000
Hz
Tone pitch strongly increasing
per m/s Vario alteration.
Setting = 4
2'500
2'000
1'500
Tone pitch only weakly
increasing per m/s Vario
alteration. Setting = 0
1'000
500
Basic tone pitch 600 Hz
0 2 4 6 8
10 12 14 m/s
2.2.6.4 Variometer Climb acoustic Pitch change / increase of tone interval per m/s
Main Setup Menu
Variometer Acoustic
Pitch change
Main Setup Menu
Variometer Acoustic
PitchMode
The interrelation may be seen on graphic below.
Range: 1 up to 5 (factory setting 2)
Number of
beep tones
er second
30
5 = Strong beep tone interval alteration
per m/s Vario alteration
25
20
= Tone interval change exponential
( Strong change from 0 – 2 m/s
15
1 = Weak beep tone interval alteration per
m/s Vario alteration
10
5
10
0 2 4 8
12 14 m/s
6
Vue de la page 14